HELP V01.01B 2000-11-14
[brasimulHelpID]
                        *** BRA SIMULATION applications ***

(1) TE-ST simulation
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal connected to the S bus (S/T interface, 4 wires).

(2) LT/NT-S/T simulation
This is a NETWORK simulation mode where the IBT-300 replaces the LT and the NT1. In this case, the connection is made on the S bus (S/T interface, 4 wires).

(3) LT-U simulation
This is a NETWORK simulation mode where the IBT-300 replaces only the LT. In this case, the connection is made on the U interface (2 wires).

(4) TE/NT-U simulation
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal and the NT1. In this case, the connection is made on the U interface (2 wires).

[bramoniHelpID]
                       *** BRA MONITORING applications ***

(1) S0/T0 monitoring 
This is a MONITORING mode where the IBT-300 test set is connected in high impedance on the S0/T0 interface (4 wires) and can non-intrusively monitor the content of the D/B channels.

(2) NT1 swap out mode
This is a MONITORING mode where the IBT-300 test set replaces the NT1. One side is connected to the U interface (2 wires) while the other side is connected to the S0/T0 interface (4 wires).

(3) U (2B1Q) repeater
The IBT-300 test set is bridged on the U interface: one side is connected to the LT (Central Office) and the other side to the NT1.

[braleasedHelpID]
                       *** BRA LEASED LINES (no D channel) applications ***

In case of leased lines (when the D channel is not used), the IBT-300 can be used to test the quality of the access. You can test the quality for circuits providing 64 kbit/s (1B), 128 kibt/s (2B) and 144 kbit/s (2B+D).

(1) TE-ST simulation
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal connected to the S bus (S/T interface, 4 wires).

(2) LT/NT-S/T simulation
This is a NETWORK simulation mode where the IBT-300 replaces the LT and the NT1. In this case, the connection is made on the S bus (S/T interface, 4 wires).

(3) LT-U simulation
This is a NETWORK simulation mode where the IBT-300 replaces only the LT. In this case, the connection is made on the U interface (2 wires).

(4) TE/NT-U simulation
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal and the NT1. In this case, the connection is made on the U interface (2 wires).

[prasimulHelpID]
                      *** PRA SIMULATION applications ***

(1) TE-S2/T2 mode
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal connected to the S2/T2 interface (maximum receiver sensitivity is set below 20 dB).

(2) LT/NT-S2/T2
This is a NETWORK simulation mode where the IBT-300 replaces the LT and the NT1. In this case, the connection is made on the S2/T2 interface (maximum receiver sensitivity is set below 20 dB).

(3) LT-U2/G.704
This is a NETWORK simulation mode where the IBT-300 replaces only the LT. In this case, the connection is made on the U interface (2MB G.703/G.704).

(4) TE/NT-U2/G.704 mode
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal and the NT1. In this case, the connection is made on the U interface (2MB G.703/G.704).

[pramoniHelpID]
                      *** PRA MONITORING applications ***

(1) S2/T2 monitoring 
This is a MONITORING mode where the IBT-300 test set is connected in high impedance on the S2/T2 interface to non-intrusively monitor the content of the D/B channels.

(2) U2/G.704 monitoring
This application allows you to use the tester on an E1 link: in this case, the receiver sensitivity is extended to 35 dB (instead of 20 dB for S2/T2 monitor).

(3) PMP monitor
This application allows you to monitor a Primary Rate Access when a Protected Monitoring Point (PMP) is provided to protect the line for in-service maintenance.

[praleasedHelpID]
       *** PRA LEASED LINES (No D-channel) applications ***

In case of leased lines (when the D channel is not used), the IBT-300 can be used to test the quality of the access. You can test the quality for circuits providing N*64 kbit/s or for an unframed 2MB circuit.

(1) TE-S2/T2 mode
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal connected to the S2/T2 interface (maximum receiver sensitivity is set below 20 dB).

(2) LT/NT-S2/T2
This is a NETWORK simulation mode where the IBT-300 replaces the LT and the NT1. In this case, the connection is made on the S2/T2 interface (maximum receiver sensitivity is set below 20 dB).

(3) LT-U2/G.704
This is a NETWORK simulation mode where the IBT-300 replaces only the LT. In this case, the connection is made on the U interface (2MB G.703/G.704).

(4) TE/NT-U2/G.704 mode
This is a TERMINAL simulation mode where the IBT-300 replaces a terminal and the NT1. In this case, the connection is made on the U interface (2MB G.703/G.704).

[prav51v52HelpID]
Not available yet.

[terminal-stHelpID]
                       *** BRA TERMINAL SIMULATION at S0/T0 ***

The IBT-300 replaces a Terminal connected on the S0/T0 interface.
Use connector [5] with cable K792 to connect the IBT-300 to the S bus.

[reseau-stHelpID]
                       *** BRA NETWORK SIMULATION at S0/T0 ***

The IBT-300 replaces a Network (replacing the LT and the NT1).
Use connector [5] with cable K792 to connect the instrument to the S bus.

WARNING: The S bus supplies power to any terminal connected to it. 
When you replace the Network with an IBT-300, you may have to use an external powerfeed box if some terminals CANNOT work without getting power from the S bus.

[terminal-uHelpID]
                       *** BRA TERMINAL SIMULATION at U ***

The IBT-300 is replacing a TE and the NT1. The IBT-300 must be connected to the U interface with cable K2508 (RJ-45 with two banana plugs).
Depending on the line code used on the U interface, the CONNECTOR is chosen as follows:
   21BQ: The most frequently used
        Use connector [4] on the rear panel.
   4B3T: Mainly for Germany, Belgium
        Use connector [20] on the right hand side.

[reseau-uHelpID]
                       *** BRA NETWORK SIMULATION at U ***

The IBT-300 is replacing a switch (LT) at the U interface.

WARNING: As most of the NT1's cannot operate without power on the U interface (around 90V is needed), you must use the adapter K2512 and two cables K2508. Plug the adapter K2512 into connector [21] on the right-hand side of the instrument.
One cable K2508 is used to connect the IBT-300 to the line (U interface), while the other K2508 is used to connect to an AC/AC adapter to supply the requested voltage.

[STHelpID]
                       *** BRA MONITORING at S0/T0 ***

Use connector [5] with cable K792 to connect the instrument to the S bus.

WARNING: The only parameter you will have to specify is the Layer 3 protocol (EDSS1, Q.SIG, CorNet(, ...) to get the right detailed decoding according to the protocol used on the ISDN access.

[NT1HelpID]
              *** BRA MONITORING at S0/T0 interface: NT1 SWAP OUT ***

1) Connection to the S bus
  Use connector [5] with cable K792.

2) Connection to the U interface
 The IBT-300 must be connected to the U interface with cable K2508 (RJ-45 with two banana plugs).
 Depending on the line code used on the U interface, the CONNECTOR is chosen as follows:
   21BQ: The most frequently used
        Use connector [4] on the rear panel.
   4B3T: Mainly for Germany, Belgium
        Use connector [20] on the right-hand side.

[UHelpID]
                       *** BRA MONITORING: U Repeater ***

The IBT-300 is bridged on the U line as follows:

1) Connection to the NT1
Use connector [21] and cable K2508 to connect the IBT-300 on the U interface towards the NT1.

2) Connection to the Central Office
Use connector [22] and cable K2508 to connect the IBT-300 on the U interface towards the Central Office.

[terminal-s2t2HelpID]
                    *** TERMINAL SIMULATION at S2/T2 (PRA, 30B+D) ***

The IBT-300 replaces a terminal equipment connected to the S2/T2 interface. As the test set operates on an ISDN primary rate access, the maximum receiver sensitivity is set to 20 dB (short haul).

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.
      
[reseau-s2t2HelpID]
      *** NETWORK SIMULATION at S2/T2 interface (PRA, 30B+D) ***

The IBT-300 replaces the network (LT+NT1) and operates on the S2/T2 interface. As the test set operates on an ISDN primary rate access, the maximum receiver sensitivity is set to 20 dB (short haul).

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.

[terminal-u2HelpID]
           *** TERMINAL SIMULATION (long haul) at S2/T2 or U2 ***

!!! WARNING (LONG HAUL)!!!: This mode will allow you to test on a primary rate access with an extended receiver sensitivity (35 dB) which will not guarantee that an ISDN terminal can operate on the line.
The IBT-300 replaces a terminal equipment connected to the S2/T2 interface or the U2 interface (if the framing is G.704).

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.
      
[reseau-u2HelpID]
          *** TERMINAL SIMULATION (long haul) at S2/T2 or U2 ***

!!! WARNING (LONG HAUL)!!!: This mode will allow to test on a primary rate access with an extended receiver sensitivity (35 dB) which will not guarantee that an ISDN terminal can operate on the line.
The IBT-300 replaces the network connected to the S2/T2 interface or the U2 interface (if the framing is G.704).

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.
   
[S2T2HelpID]
                     *** PRA MONITORING at S2/T2 ***

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.

[U2G704HelpID]
                      *** PRA MONITORING at E1 ***

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.

[U2PMPmoniHelpID]
                *** PRA MONITORING: Protected Monitoring Point (PMP) ***

How to connect the IBT-300?
---------------------------
RJ-45 (SYMMETRICAL CONNECTION)
Use connector [6] and cable K792 to connect the instrument to the line. Make sure that the selected impedance is 120 ohms by pressing ALT+F1 to access the Installation menu.

BNC (ASYMMETRICAL CONNECTION)
Use connectors [7] and [8] with BNC cables. Make sure that the selected impedance is 75 ohms by pressing ALT+F1 to access the Installation menu.

[PMPmoniHelpID]


[G703G704HelpID]


[testseqHelpId]
                                *** TEST SEQUENCER ***

PURPOSE: This test provides an AUTOMATIC TEST SEQUENCE which is used to run several ISDN basic tests in sequence.
   
    (PART -1-) Configuring and launching a test
    (PART -2-) Saving and editing test results
___________________________________________
(PART -1) CONFIGURING AND LAUNCHING A TEST

   SoftKeys: { F1: Profile },  { F2: Last },  { F4: Select },  { F5: Run }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application, you can 'save / rename/ delete or load' a specific profile.

 F2: LAST
Reviews the results of the last test.

 F4: SELECT
Once you have chosen to include an ISDN basic test (such as BERT, B-channel configuration, ...) in your test sequence you can:
  -> Run the basic ISDN test with its current parameters
  -> Run the basic ISDN test with a profile (if you have already defined some).

 F5: RUN
Starts the test sequence.

___________________________________________
(PART -2) SAVING AND EDITING TEST RESULTS

During the test sequence you can skip an ISDN basic test by pressing {F4: Next}.
When the test sequence is complete, you can store the results in a file.

   SoftKeys: { F1: Store }, { F5: Quit }

 F1: STORE
Stores test results in a file. The file manager application allows you to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file by using the file manager application. First choose 'Tools > File Manager' from the menu bar to launch the file manager. Then browse to the file you want and display it by pressing the Enter key.

 F5: QUIT
Returns to the application.

[phoneHelpId]
                       *** MAKING CALLS ***
  
PURPOSE: This test allows you to manually place one or several call(s) (up to 2 for the basic and up to 30 for primary rate access). You can also generate DTMF and activate supplementary services using the KEYPAD protocol. 
Two dialing modes are supported: En-bloc and Overlap.

Use the directional keys UP and DOWN to move from one call to another.

   (PART -1-) Making a call
   (PART -2-) Making several calls/ releasing calls
___________________________________________
(PART -1) MAKING A CALL

   SoftKeys: { F1: Profile }, { F3: Memo }, { F5: Call }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application you can 'save / rename/ delete or load' a specific profile.

 F3: MEMO
Gives access to a phone book.

 F5: CALL
Once you have set all parameters, press this key to start the call.

___________________________________________
 (PART -2) MAKING SEVERAL CALLS / RELEASING CALLS

   SoftKeys: { F2: Chan }, { F3: Stat }, { F4: Newcall }, { F5: Break }

 F2: CHAN
Displays a graphical view of the ISDN access (B-channel matrix). You can also use this matrix to move to a specific B channel.

 F3: STAT
Provides more information on the call.

 F4: NEWCALL
Initiates a new call. Use the ESC key to cancel and go back to a connected call.
 
 F5: Break
Disconnects the call.

[bertHelpId]
                  *** Testing Quality (BERT) ***
  
PURPOSE: This test provides a test of the quality of an ISDN access. The evaluation can be performed using the G.821 recommendation or with a simple method by using a threshold.
The BERT evaluation is started automatically when the call is established.

   (PART -1-) Configuring the test
   (PART -2-) Running the test
   (PART -3-) Saving and editing test results
___________________________________________
(PART -1) CONFIGURING THE TEST

   SoftKeys: { F1: Profile }, { F2: Last }, { F4: Start }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application you can 'save / rename/ delete or load' a specific profile.

 F2: LAST
Displays the results of the last test (empty if none).

 F4: START
Starts the BER Test.
  While the test is running, the IBT-300 displays the results in absolute values and percentage.
  You can also inject errors to check the continuity for instance.
_________________________________________
(PART -2) RUNNING THE TEST

  SoftKeys: { F2: Error }, { F5: Stop }

 F1: ERROR
Used to inject errors (only available if you have enabled the manual insertion of errors).

 F5: STOP
Breaks the test.
_________________________________________
(PART -3) SAVING AND EDITING TEST RESULTS

  SoftKeys: { F1: Store }, { F5: Quit }

 F1: STORE
Stores test results in a file. The file manager application allows to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file by using the file manager application. First choose 'Tools > File Manager' from the menu bar to launch the file manager. Then browse to the file you want and display it by pressing the Enter key.

 F5: QUIT
Returns to the application.

[servHelpId]
                  *** Testing ISDN services and teleservices ***
  
PURPOSE: This test provides an AUTOMATIC TEST to quickly verify which services/teleservices are available on the access. You can also use the <phone> function to place a call with a specific service/teleservice.

   (PART -1-) Configuring and launching a test
   (PART -2-) Saving and editing test results
___________________________________________
(PART -1) CONFIGURING AND LAUNCHING A TEST

   SoftKeys: { F1: Profile }, { F2: Last }, { F3: Select }, { F4: Start }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application you can 'save / rename/ delete or load' a specific profile.

 F2: LAST
Displays the results of the last test (empty if none).

 F3: SELECT
Depending on the Layer 3 Protocol you may have chosen, a specific list of services/services is available. In addition you can create up to three user-defined services (User1, User2, User3). 

 F4: START
Starts the automatic test sequence. 
While the test is running, the IBT-300 displays the result ('Passed' or 'Failed') for each service being tested.

     'Passed': the call for the specified service was established and released successfully.
     'Failed': The call could not be established or released with an abnormal cause.
_________________________________________
(PART -2) SAVING AND EDITING TEST RESULTS

Once the automatic test sequence is completed, you can store and edit test results.

    SoftKeys: { F1: Store }, { F4 : Quit }

 F1: STORE
Stores test results in a file. The file manager application allows you to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file by using the file manager application. First choose 'Tools > File Manager' from the menu bar to launch the file manager. Then browse to the file you want and display it by pressing the Enter key.

 F5: QUIT
Returns to the test function.

[suppservHelpId]

                  *** Testing availability of ISDN supplementary services ***
  
PURPOSE: This test provides an AUTOMATIC TEST to quickly verify which ISDN supplementary services are available on the access. 

WARNING: This test must be carried out using the address equipment you are replacing. This means that you have to call yourself.

   (PART -1-) Configuring and launching a test
   (PART -2-) Saving and editing test results
___________________________________________
(PART -1) CONFIGURING AND LAUNCHING A TEST

   SoftKeys: { F1: Profile }, { F2: Last }, { F3: Select }, { F4: Start }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application you can 'save / rename/ delete or load' a specific profile.

 F2: LAST
Displays the results of the last test (empty if none).

 F3: SELECT
You can choose which supplementary services you want to test by defining a subset. Tick each supplementary service you want to test and untick each supplementary service you want to ignore.

 F4: START
Starts the automatic test sequence. While the test is running, the IBT-300 displays the result ('Passed' or 'Failed') for each service being tested.
     'Failed':     The call could not be established or released with an abnormal cause.
  
     'Available':   The supplementary service is available on the access. So the customer can use it.
     
     'Unavailable': The supplementary service is not available on the access. So the customer will not able to use it.

     '????':        The test procedure provides no definitive answer as to service availability.
          
_________________________________________
(PART -2) SAVING AND EDITING TEST RESULTS

Once the automatic test sequence is completed, you can store and edit test results.

    SoftKeys: { F1: Store }, { F4: Quit }

 F1: STORE
Stores test results in a file. The file manager application allows you to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file by using the file manager application. First choose 'Tools > File Manager' from the menu bar to launch the file manager. Then browse to the file you want and display it by pressing the Enter key.

 F5: QUIT
Returns to the test function.

[bchannelHelpId]
                  *** Testing B-channel provisioning ***
  
PURPOSE: This test provides an AUTOMATIC TEST to quickly verify the configuration/provisioning of the B channels.
Three different B-channel test types are available.

   (PART -1-) Configuring and launching a test
   (PART -2-) Saving and editing test results
___________________________________________
(PART -1) CONFIGURING AND LAUNCHING A TEST

   SoftKeys: { F1: Profile }, {F5: Start }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application, you can 'save / rename/ delete or load' a specific profile.
 
 F5: START   
Choose one of the B-channel test type.
F5 starts the test. If you have selected the 'Multiple call' test, then you must enter a destination address 'Called address').

___________________________________________
(PART -2) SAVING AND EDITING TEST RESULTS

Once the automatic test sequence is completed, you can store and edit test results.

 F1: STORE
Stores test results in a file. The file manager application allows you to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file by using the file manager application. First choose 'Tools > File Manager' from the menu bar to launch the file manager. Then browse to the file you want and display it by pressing the Enter key.

[X25DsimHelpId]



[X25BsimHelpId]



[isdnrespHelpId]
                       *** ISDN Responder ***

The IBT-300 offers an unattended mode with automatic call back (up to 2 calls for BRA and up to 30 calls for PRA). 
In this mode, the IBT-300 tries to systematically call back any address for which a call was set-up.

Once you have selected the parameters, press F5 to start. The IBT-300 will display information regarding the calls.

If you want to get a GRAPHICAL VIEW, press the STATUS key (the unmarked key on the left-hand side below the screen). Then press {F1: Matrix} to display the B-channel matrix.

[X25respHelpId]
                     *** X.25/D Responder ***

The IBT-300 offers an unattended mode for automatic acceptance of one incoming call.

Press {F5: Run} to start the test.

[callbackHelpId]
                    *** ISDN Call-back ***

The IBT-300 offers an unattended mode with automatic call-back (up to 2 calls for BRA and up to 30 calls for PRA). 
In this mode, the IBT-300 tries to systematically call back any address for which a call was set-up.

Once you have selected the parameters, press F5 to start. The IBT-300 will display information regarding the calls.

If you want to get a GRAPHICAL VIEW, press the STATUS key (the unmarked key on the left-hand side below the screen). Then press {F1: Matrix} to display the B-channel matrix.

[dmonHelpId]
           *** On-screen D-channel monitoring ***

The IBT-300 can monitor the D channel in both directions and can decode the Layer1, Layer2 and Layer3.
In addition an AUDIO-MONITOR function is provided to listen to the content of any B channel.
The D-channel protocol can be viewed in three modes: SUMMARY, DETAILED or HEXA.
 
   (PART -1-) Using filters
   (PART -2-) Starting on-line (real-time) monitoring
   (PART -3-) Off-line analysis
   (PART -4-) Saving and retrieving monitoring files
___________________________________________
(PART -1) USING FILTERS 

   SoftKeys: { F1:Profile }, { F2:Reset }, { F3: Read }, { F5: Run }

 F1: PROFILE
Parameters used for this test can be stored in a file called a 'profile'. You can create several profiles to build a test library in order to test quickly and efficiently. Using the profile manager application, you can 'save / rename/ delete or load' a specific profile.
To use a predefined profile, first use {F1: Profile} to enter the profile manager then select one profile from the list and press {F1: Load} to apply it.

 F2: RESET
Resets the filters to the default configuration (no-filters).

 F3: READ
Allows you to load a monitoring or a trace file from the file manager application for off-line analysis.

 F5: RUN
Starts the on-line monitoring of the ISDN access.

___________________________________________
(PART -2) STARTING ON-LINE MONITORING
When you have defined filters (if necessary), press {F5: RUN} to start monitoring the ISDN access.

   SoftKeys: { F1:B31 }, { F2:B1 }, { F3:Susp/Resu }, { F5:Break }

 F1: Bx    F2: By
Use these softkeys to listen to a specific B channel for AUDIO MONITOR.

 F3: SUSP/RESU
Once the analysis has begun, you can freeze the display by pressing F3 (the instrument keeps capturing data). To resume press F3 again.

 F4: BREAK
To stop capturing, press F4. Then you can perform an off-line analysis using different filters and store the captured data in a file.

___________________________________________
(PART -3) OFF-LINE ANALYSIS

To navigate through the file you can move one page up or down by using ALT+UP or ALT+DOWN. 
To jump directly to a line, type the number of the line on the keypad and press Enter.

The default display mode is SUMMARY. To enter the DETAILED mode, press Enter.

___________________________________________
(PART -4) SAVING AND RETRIEVING MONITORING FILES

Press { F2: Store } to store the capture in a file. The file manager application allows you to create/rename and delete directories so you can choose where you want to store the file.
Later on you can view a file using the read function (See PART -2).

[dmonpcHelpId]
            *** D-channel monitoring on PC with ISDNpartner ***

The IBT-300 can be used as a high-end D-channel analyzer on PC when combined with the ISDNpartner software (Expert System).
Connect the IBT-300 to a PC using the K766 cable. You can define the bitrate of the serial port by choosing <Preferences > Serial Port > Baud Rate> from the menu bar (press the MENU key to make this menu bar appear on top of the screen).

 F5: RUN/BREAK
To start the synchronization with the ISDNpartner software, press F5. The display shows 'Synchronizing' while connecting to the ISDNpartner application. Then use ISDNpartner to perform an expert analysis.


[bmonHelpId]




[bmonpcId]